RSV

Repair and reinforcement saddle, SDR11

Repair and reinforcement saddle RSV SDR 11

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100
  • 2 combined saddle components
  • Safety technology

Note:

Only apply to minor pipe damage.

The damage must be located within the repair area and not in the fusion zone.

Go back

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d1 d2 B1 H H t Weight kg BX PU
615164 90 50 155 148 148 21 0,930 24 192
615165 110 50 178 170 170 21 1,160 16 128
615166 125 50 190 183 183 21 1,370 15 120
615168 160 50 225 218 218 21 1,680 10 80
615169 180 50 240 238 238 21 1,810 6 48
615170 200 50 250 258 258 21 1,860 5 40
615171 225 50 255 283 283 21 1,910 5 40

FRIALEN safety fittings can be fused with SDR levels 11 to 17.6. Other levels of SDR can be processed on request. Please note the mandatory labels directly on the product. DVGW test mark issued: DV-8606AU2249

Areas of Application

The FRIALEN-Repair and Reinforcing Saddles are used for the repair of minor pipe damages.

Assembly Instructions

The fusion of the HD-PE pipe with the FRIALEN-Repair and Reinforcing Saddle takes place by FRIALEN-fusing – leakproof and longitudinally strong.

In order to avoid discharge of media, the leak has to be sealed with a separate plug (≤ d2).

Both HD-PE saddles have to be prepared according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”). This includes removing the oxide layer and cleaning the pipe covered by the saddles.

Good reasons for using the FRIALEN-VVS:

  • Compact construction

  • HD-PE saddle with exposed heating element for optimal heat transfer

  • Sealing area free of heating wires

  • Preassembled unit without loose parts

  • Extra wide fusion zone

  • Additional barcode for tracing back the fitting (Traceability-Coding)

Downloads