Fusion unit without documentation function
Powerful universal fusion unit FRIAMAT 7 basic
- State-of-the-art converter technology with active cooling.
- Bright colour TFT display
- With mini scanner or 1D/2D scanner (2D barcodes according to ISO 12176-5)
- Extra long fusion cable (4 m)
- Extra long power cable (5 m)
- Weight approx. 12.8 kg
Note:
Possibility of updating the FRIAMAT software via the USB interface by the user.
Reference | Article description | Weight kg | BX | PU |
---|---|---|---|---|
611130 | With mini scanner | 14,900 | 1 | 4 |
613130 | With reader wand | 14,900 | 1 | 4 |
614130 | With 1D/2D scanner | 14,900 | 1 | 4 |
Technical data 1) |
FRIAMAT 7 basic |
Type of device |
Universal fusion unit without documentation function |
Model with mini scanner |
Order no. 611130 |
Model with reader wand |
Order no. 613130 |
Model with 1D/2D scanner |
Order no. 614130 |
Maximum diameter |
Up to d 1200 2) |
Input voltage section |
AC 190 V – 250 V |
Frequency range |
44 Hz … 66 Hz |
Current consumption |
AC 16 A maximum |
Power |
3.5 kW |
Unit fuse |
16 A sluggish |
Welding tension |
8 – 48 V |
Output current |
maximum 110 A |
Welding current monitoring |
Short circuit and interruption |
Barcode type |
1D-Code 2/5 interleaved 2D-Code (QR; Aztec; Data Matrix) according to ISO 12176-5 |
Interface |
USB |
Documentation of fusion data |
No |
Documentation of traceability data |
No |
Data memory |
- |
Log format |
- |
Manual emergency barcode input |
Yes |
FRIAMAT preCHECK function |
Yes |
Software update via USB interface |
Yes |
Fusion-Pass |
No |
Supervisor-Pass |
No |
Start/stop pass for remote control |
Optional (Order no. 624003) |
Working temperature range |
-20 °C ... +50 °C |
Language variants |
23 |
Connection cable |
5 m with contour plug |
Fusion cable |
4 m with connection plug Ø 4 mm |
Weight |
approx. 12.8 kg |
Dimensions W x D x H |
260 x 500 x 340 mm |
Casing |
Protection category IP 54 / protection category I |
Approval / quality |
CE, ISO 9001, WEEE Reg. No. DE 49130851, RoHS |
Accessories |
Operating instructions, transport box |
1) Subject to technical modifications.
2) With FRIAMAT 7 basic, FRIALEN and FRIAFIT safety fittings up to d 900 can be fused in the entire working temperature range from -20 °C to +50 °C.
Utilising processing fittings from other manufacturers is possible even up to d 1200 and possibly larger. However, the specific power requirement of the fitting at the prevailing processing temperature must always be clarified beforehand with the fitting manufacturer.
- Powerful electrofusion unit with state-of-the-art converter technology and flow-optimized, active cooling.
- High-resolution, extremely bright 4.3 “TFT color display.
- With mini-scanner, reader wand or new 1D/2D scanner for reading 2D barcodes according to ISO 12176-5, Adapter bag, language selection, adjustable buzzer volume, manual emergency entry. Extra-long power cable (4 m) and extra-long fusion cable (5 m). Weight approx 12,8 kg.
- Continuous monitoring of the entire fusion process and all device functions.
- With FRIAMAT preCHECK function: The most advanced way to fuse with foresight. The FRIAMAT automatically determines whether the next fusion can be performed completely to the end.
- The user himself can install software updates via USB interface.