UB SDR 11

Coupler without inner stop, SDR 11

Coupler UB SDR 11 without inner stop

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100
  • Safety technology
  • Large insertion depth for good pipe routing (no holding devices required)
  • DVGW test mark: DV-8601AU2248, DV-8606AU2249, DV-8611AU2250 and DW-8610CN04200
  • FM Approvals Class: 1613 (d 63 - d 500)

Note:

From nominal size 400 with separate fusion zone and preheating technology.

Go back

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d SDR range B D h L t Weight kg BX PU
616577 16 11 - 7,4 45 29 16 60 30 0,030 135 4320
612662 32 11 - 7,4 61 45 21 77 39 0,070 60 1920
612663 40 11 - 7,4 71 54 23 86 43 0,090 40 1280
612664 50 11 - 17,6 82 68 27 98 49 0,150 25 800
612665 63 11 - 17,6 96 82 29 112 56 0,230 15 480
612666 75 11 - 17,6 110 98 32 122 61 0,330 50 400
612667 90 11 - 17,6 127 114 51 157 78 0,440 30 240
612668 110 11 - 17,6 152 137 49 159 79 0,710 24 192
612669 125 11 - 17,6 169 156 46 172 86 0,940 16 128
615001 140 11 - 17,6 185 174 52 184 92 1,270 12 96
612671 160 11 - 17,6 207 199 52 190 95 1,770 8 64
612672 180 11 - 17,6 228 220 63 210 105 2,090 6 48
612673 200 11 - 17,6 252 247 63 220 110 2,800 1 56
612674 225 11 - 17 280 277 57 236 118 3,890 1 36
617278 250 11 - 17,6 309 309 66 247 123,5 5,800 1 24
617279 280 11 - 17,6 344 344 66 269 134,5 7,400 1 18
1 612670 315 11 - 17,6 390 390 78 300 150 10,050 1 18
2 615074 355 11 - 17,6 445 445 68 300 150 14,600 1 9
615075 400 9 - 17,6 500 500 90 320 160 20,800 1 4
615076 450 9 - 17,6 560 560 79 340 170 30,000 1 4
615124 500 9 - 17,6 630 630 80 360 180 39,800 1 2
616312 560 9 - 17,6 715 715 95 380 190 55,000 1 2
616269 630 9 - 17,6 810 810 101 420 210 79,600 1 2
616313 710 11 - 17,6 900 900 108 442 210 118,800 1 1
616314 800 11 - 17,6 1000 1000 136 500 250 138,800 1 1
616440 900 11 - 17,6 1130 1130 165 600 300 210,300 1 1
616989 1000 11 1200 1200 171 680 340 121,000 1 1
1 new design up to Q2/2025
2 new design up to Q4/2025

Please note the mandatory labels directly on the product. DVGW test marks issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU22500.

Areas of Application

The FRIALEN-Coupler UB is used for cut and lay pipe connections.

Additional areas of application:

  • Integration of adapters into an existing pipeline
  • Connection of pipelines with fixed or restraint points
  • Reinforcement / sealing of localised pipe damage
  • Reinforcement of pinch points on small dimensions

Assembly Instructions

The fusion of pipe ends with the FRIALEN-Coupler UB takes place using FRIALEN-fusing – leakproof and longitudinally strong.

The pipe ends are prepared according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225” and “FRIALEN-Special Technology for laying large bore pipes and relining pipe networks”). This involves removing the oxide skin and cleaning the pipe ends. Please note that spigot of valves must be at least half as long as the coupler.

To compensate a larger annular gap (> 1 mm, max. 3 mm) between coupler and pipe, the pre-heating barcode can be used for couplers UB from d 400 (see instructions packed up with the coupler).

For removal of the oxide layer, FWSG scraper tools are available which facilitate a uniform swarf removal and a reproducible quality of the fusion area preparation.

Good reasons for using the FRIALEN-Slide-over Coupler UB:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)
  • Extra wide fusion zones
  • Maximum stability through great wall thickness
  • Cold zones at the front side and in the middle of the coupler
  • Exposed heating coil for direct heat transmission to the pipe
  • Small annular gap for build-up of optimum joining pressure in the fusion zone
  • Touch proof electric contacts
  • Fusion indicators for visual fusion control
  • From d 400: pre-heating technique for a optimal gapbridging
  • From d 400: External reinforcement for an ideal fusion pressure
  • Durable batch marking
  • Individually wrapped for dirt protection
  • Additional barcode for tracing back the fitting (Traceability-Coding).

Downloads